7CF2 Transducer
Frequency Bandwidth: 2 — 7 MHz
ExamTypes: Abdomen, Fetal Echo, OB/GYN, Pelvis, Renal
DesignAttributes:
Lightweight transducer with flexible cable
Ergonomically designed form factor
User selectable MultiHertz™ multiple frequency imaging
Wide bandwidth curved array volume transducer
|
6C2 Transducer
Frequency Bandwidth: 2 — 6 MHz
CompatibleWith: ACUSON Sequoia™ ultrasound system
ExamTypes: Abdomen, Fetal Echo, OB/GYN, Pediatric Abdomen, Pelvis, Peripheral Vascular, Renal
DesignAttributes:
Curved Vector Format
Hanafy lens transducer technology
Ergonomically designed form factor
|
4C1 Transducer
Frequency Bandwidth: 1 — 4.5 MHz
CompatibleWith: ACUSON Sequoia ultrasound system, ACUSON Aspen™ ultrasound system
ExamTypes: Abdomen, Fetal Echo, OB/GYN, Pelvis, Renal
DesignAttributes:
Curved Vector Format
Hanafy lens transducer technology
User selectable MultiHertz imaging
|
9EVF4 Transducer
Frequency Bandwidth: 4 — 9 MHz
ExamTypes: Fetal Echo, Neonatal Head, OB/GYN
DesignAttributes:
Wide bandwidth endovaginal volume transducer
Lightweight transducer with flexible cable
|
EC9-4 Transducer
Frequency Bandwidth: 3.75 — 9 MHz
ExamTypes: Neonatal Head, OB/GYN, Prostate
DesignAttributes:
Ergonomically designed form factor
Lightweight transducer with flexible cable
|
EV-8C4 Transducer
Frequency Bandwidth: 4 — 9 MHz
ExamTypes: Endovaginal gynecology, endovaginal obstetrics
Features:
Tightly curved format
Wide field-of-view
User-selectable Wideband MultiHertz imaging
Harmonic Compounding
|
4P1 Transducer
Frequency Bandwidth: 1 — 4.5 MHz
ExamTypes: Abdomen, Adult Echo, Fetal Echo, OB/GYN, Pediatric Echo, Pelvis, Renal, Transcrania
Design Attributes:
Multi-D™ matrix array transducer
Ergonomically designed form factor
Lightweight transducer with flexible cable
|
10V4 Transducer
Frequency Bandwidth: 4 — 10 MHz
CompatibleWith: ACUSON Sequoia ultrasound system
ExamTypes: Neonatal Echo, Neonatal Head, Pediatric Abdomen, Pediatric Echo, Pelvis, Rena
Design Attributes:
Vector™ wide-view imaging format
User selectable MultiHertz imaging |
8V3 Transducer
Frequency Bandwidth: 2.5 — 8 MHz
CompatibleWith: ACUSON Sequoia ultrasound system
ExamTypes: Fetal Echo, Neonatal Echo, Neonatal Head, Pediatric Abdomen, Pediatric Echo
Design Attributes:
Hanafy lens transducer technology
Vector imaging format
User selectable MultiHertz imaging
|
4V1 Transducer
Frequency Bandwidth: 1 — 4.5 MHz
CompatibleWith: ACUSON Sequoia ultrasound system, ACUSON Aspen ultrasound system
ExamTypes: Abdomen, Fetal Echo, OB/GYN, Pelvis, Renal
Design Attributes:
Hanafy lens transducer technology
User selectable MultiHertz imaging
|
4V1C Transducer
Frequency Bandwidth: 1 — 4.5 MHz
CompatibleWith: ACUSON Sequoia ultrasound system
ExamTypes: Adult Echo, Pediatric Echo
Design Attributes:
Hanafy lens transducer technology
Vector imaging format
User selectable MultiHertz imaging
RF shielding
|
18L6 HD Transducer
Frequency Bandwidth: 5.5 — 18 MHz
ExamTypes: Breast, Cerebrovascular, Digital, Musculoskeletal, Penile, Peripheral Vascular, Testicle, Thyroid
Design Attributes:
Hanafy lens transducer technology
Patented ergonomic design with Elastogrip™ ergonomic grip coating
Extra-long cable (2.1 m) for ease of use
|
14L5 SP Transducer
Frequency Bandwidth: 5 — 14 MHz
Selectable 2D Frequencies: 6.0, 10.0, 14.0 MHz
Selectable THI Frequencies: 11.0, 14.0 MHz
Selectable Color Doppler Frequencies: 5.5, 6.25, 7.5 MHz
Selectable PW Doppler Frequencies: 5.5, 6.25, 7.5 MHz
2D Steering Angle: max +/- 20°
Color Doppler Steering Angle: max +/- 20°
PW Doppler Steering Angle: max +/- 20°
Number of Elements: 128
Footprint: 26 mm
Maximum Field of View: 40°
Maximum Display Depth: 60 mm
Biopsy Guide: Not Available
Exam Types: Breast, Cerebrovascular, Digital, Intraoperative Abdomen, Intraoperative Vascular, Musculoskeletal, Testicle, Thyroid
Design Attributes:
Lightweight transducer with flexible cable
Ergonomically designed form factor
Virtual format imaging
Sterilizable high resolution linear array for special applications
|
14L5 Transducer
Frequency Bandwidth: 5 — 14 MHz
Exam Types: Breast, Cerebrovascular, Digital, Musculoskeletal, OB/GYN, Pediatric Abdomen, Pediatric Hip, Penile, Peripheral Vascular, Testicle, Thyroid
Design Attributes:
Multi-D matrix transducer
Ergonomically designed form factor
Lightweight transducer with flexible cable
Virtual format imaging |
9L4 Transducer
Frequency Bandwidth: 4 — 9 MHz
Compatible With: ACUSON Sequoia ultrasound system
Exam Types: Breast, Cerebrovascular, Digital, Musculoskeletal, OB/GYN, Pediatric Abdomen, Pediatric Hip, Pelvis, Penile, Peripheral Vascular, Renal, Testicle, Thyroid
Design Attributes:
Multi-D matrix transducer
Ergonomically designed form factor
Lightweight transducer with flexible cable
|
V5Ms Transducer
Frequency Bandwidth: 3 — 7 MHz
Compatible With: ACUSON X300™ ultrasound system, ACUSON X300 ultrasound system, premium edition, ACUSON Sequoia ultrasound system, ACUSON Antares™ ultrasound system, ACUSON CV70™ cardiovascular system, ACUSON Cypress™ cardiovascular system, ACUSON Aspen ultrasound system, ACUSON 128XP/10C™ echocardiography system
Exam Types: Transesophageal Echo
Design Attributes:
Endoscope diameter = 10.5 mm, length = 110 cm
Adult tip size: width = 14.5 mm, height = 11.5 mm
Ergonomic design featuring one-hand control with variable speed rotation — 90° per sec
RF shielding
|
CW5 Transducer
Selectable CW Doppler Frequencies: 3 — 7 MHz
Compatible With: ACUSON Antares ultrasound system, ACUSON X500™ ultrasound system, ACUSON X300 ultrasound system, SONOLINE G60 S™ ultrasound system, ACUSON CV70 cardiovascular system
Exam Types: Adult Echo, Cerebrovascular, Neonatal Echo, Peripheral Vascular, Pediatric Echo, Transcranial |
CW2 Transducer
Compatible With: ACUSON Antares ultrasound system, ACUSON X500™ ultrasound system, ACUSON X300 ultrasound system, SONOLINE G60 S™ ultrasound system, ACUSON CV70 cardiovascular system
Exam Types: Adult Echo, Cerebrovascular, Neonatal Echo, Peripheral Vascular, Pediatric Echo, Transcranial |